Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 278(8): 2823-2828, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32948894

RESUMO

PURPOSE: Refinement currently offered in new sound processors may improve noise listening capability reducing constant background noise and enhancing listening in challenging signal-to-noise conditions. This study aimed to identify whether the new version of speech processor preprocessing strategy contributes to speech recognition in background noise compared to the previous generation processor. METHODS: This was a multicentric prospective cross-sectional study. Post-lingually deaf adult patients, with at least 1 year of device use and speech recognition scores above 60% on HINT sentences in quiet were invited. Speech recognition performance in quiet and in noise with sound processors with previous and recent technologies was assessed under four conditions with speech coming from the front: (a) quiet (b) fixed noise coming from the front, (c) fixed noise coming from the back, and (d) adaptive noise ratios with noise coming from the front. RESULTS: Forty-seven cochlear implant users were included. No significant difference was found in quiet condition. Performance with the new processor was statistically better than the previous sound processor in all three noisy conditions (p < 0.05). With fixed noise coming from the back condition, speech recognition was 62.9% with the previous technology and 73.5% on the new one (p < 0.05). The mean speech recognition in noise was also statistically higher, with 5.8 dB and 7.1 dB for the newer and older technologies (p < 0.05), respectively. CONCLUSION: New technology has shown to provide benefits regarding speech recognition in noise. In addition, the new background noise reduction technology, has shown to be effective and improves speech recognition in situations of more intense noise coming from behind.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Estudos Transversais , Humanos , Estudos Prospectivos , Fala
2.
Braz. j. otorhinolaryngol. (Impr.) ; 85(4): 502-509, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019574

RESUMO

Abstract Introduction: The conventional evaluation of neural telemetry and impedance requires the use of the computer coupled to an interface, with software that provides visualization of the stimulus and response. Recently, a remote control (CR220®) was launched in the market, that allows the performance of intraoperative tests with minimal instrumentation. Objective: To evaluate the agreement of the impedance values and neural telemetry thresholds, and the time of performance in the conventional procedure and by the remote control. Methods: Multicentric prospective cross-sectional study. Intraoperative evaluations of cochlear implants compatible with the use of CR220® were included. The tests were carried out in the 22 electrodes to compare the time of performance in the two situations. The agreement of the neural telemetry threshold values obtained from five electrodes was analyzed, and the agreement of impedance was evaluated by the number of electrodes with altered values in each procedure. Results: There were no significant difference between the impedance values. There was a moderate to strong correlation between the electrically-evoked compound action potential thresholds. The mean time to perform the procedures using the CR220 was significantly lower than that with the conventional procedure. Conclusion: The use of the CR220 provided successful records for impedance telemetry and automatic neural response telemetry.


Resumo Introdução: A avaliação convencional da telemetria neural e de impedâncias implica o uso do computador acoplado a uma interface, o software fornece o estímulo e a visualização das respostas. Recentemente, foi lançado um controle remoto (CR220®), que possibilita testes intraoperatórios com instrumental mínimo. Objetivo: Avaliar a concordância dos valores das impedâncias e dos limiares da telemetria neural e o tempo de execução no procedimento convencional e pelo controle remoto. Método: Estudo prospectivo transversal multicêntrico. Foram incluídas as avaliações intraoperatórias de implante coclear compatível com o uso do CR220®. Os testes foram realizados nos 22 eletrodos para comparar os tempos de execução nas duas situações. Foi analisada a concordância dos valores do limiar da telemetria neural obtidos em cinco eletrodos e a concordância das impedâncias foi avaliada pelo número de eletrodos com valores alterados em cada procedimento. Resultados: Não houve diferença significante entre as impedâncias. Obteve-se moderada a forte correlação entre os limiares do potencial de ação composto eletricamente evocado. O tempo médio para os procedimentos com o CR220 foi significativamente menor do que com o procedimento convencional. Conclusão: O uso do CR220 proporcionou registros bem-sucedidos para a telemetria de impedância e a telemetria automática de respostas neurais.


Assuntos
Humanos , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Telemetria/instrumentação , Implantes Cocleares , Implante Coclear/instrumentação , Surdez/cirurgia , Limiar Auditivo , Testes de Impedância Acústica , Estudos Transversais , Estudos Prospectivos , Implante Coclear/métodos , Surdez/etiologia , Potenciais Evocados Auditivos
3.
Braz J Otorhinolaryngol ; 85(4): 502-509, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29858159

RESUMO

INTRODUCTION: The conventional evaluation of neural telemetry and impedance requires the use of the computer coupled to an interface, with software that provides visualization of the stimulus and response. Recently, a remote control (CR220®) was launched in the market, that allows the performance of intraoperative tests with minimal instrumentation. OBJECTIVE: To evaluate the agreement of the impedance values and neural telemetry thresholds, and the time of performance in the conventional procedure and by the remote control. METHODS: Multicentric prospective cross-sectional study. Intraoperative evaluations of cochlear implants compatible with the use of CR220® were included. The tests were carried out in the 22 electrodes to compare the time of performance in the two situations. The agreement of the neural telemetry threshold values obtained from five electrodes was analyzed, and the agreement of impedance was evaluated by the number of electrodes with altered values in each procedure. RESULTS: There were no significant difference between the impedance values. There was a moderate to strong correlation between the electrically-evoked compound action potential thresholds. The mean time to perform the procedures using the CR220 was significantly lower than that with the conventional procedure. CONCLUSION: The use of the CR220 provided successful records for impedance telemetry and automatic neural response telemetry.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Surdez/cirurgia , Telemetria/instrumentação , Testes de Impedância Acústica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Limiar Auditivo , Criança , Pré-Escolar , Implante Coclear/métodos , Estudos Transversais , Surdez/etiologia , Potenciais Evocados Auditivos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
4.
Braz J Otorhinolaryngol ; 79(3): 298-305, 2013.
Artigo em Inglês, Português | MEDLINE | ID: mdl-23743744

RESUMO

UNLABELLED: Cochlear implants represent a significant breakthrough in the treatment of hearing loss. Evidence indicates bilateral hearing brings significant benefits to patients, particularly when binaural hearing is offered. OBJECTIVE: To describe the first case of implantation of a Digisonic SP® Binaural Neurelec device in Brazil (the third implant placed in the Americas, after Mexico and Colombia) and the chosen surgical approach. METHOD: Description of a surgical approach. RESULTS: The procedure was successfully completed. DISCUSSION: The squelch effect, binaural summation, location of the sound source, and the shadow effect of the head are listed among the reasons to explain the superiority of binaural rehabilitation. Cost of treatment must be considered in the development of public health policies. CONCLUSION: The cost of cochlear implants has been one of the main impediments to bilateral rehabilitation. The Digisonic SP® Binaural Neurelec device addresses this issue and exposes patients to less risk through a minimally invasive implantation procedure.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva Bilateral/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Adulto , Implante Coclear/instrumentação , Feminino , Humanos , Masculino , Localização de Som , Percepção da Fala , Resultado do Tratamento
5.
Braz. j. otorhinolaryngol. (Impr.) ; 79(3): 298-305, maio-jun. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-675683

RESUMO

O implante coclear é um grande avanço no tratamento da surdez. Há grandes evidências que a audição bilateral traz diversas vantagens ao ser humano e muito mais quando se trata de audição binaural. OBJETIVO: Este artigo tem por objetivo descrever o primeiro caso operado no Brasil, sendo o terceiro país das Américas (México e Colômbia) a realizar, com implante binaural Neurelec Digisonic SP® demonstrando a técnica cirúrgica. MÉTODO: Descrição da técnica cirúrgica. RESULTADOS: Ver técnica cirúrgica. Procedimento ocorreu sem intercorrências. DISCUSSÃO: O efeito "squelch", a somação binaural, a localização da fonte sonora e o efeito sombra da cabeça são umas das principais razões que justificam a superioridade da reabilitação binaural. O custo do tratamento deve ser levado em conta em políticas de saúde pública. CONCLUSÃO: Custo do implante coclear é um dos grandes limitadores da bilateralidade na reabilitação desse grupo de pacientes, porém, com essa tecnologia, é possível solucionar esse problema, expondo o paciente a poucos riscos, com o uso de uma técnica cirúrgica pouco invasiva.


Cochlear implants represent a significant breakthrough in the treatment of hearing loss. Evidence indicates bilateral hearing brings significant benefits to patients, particularly when binaural hearing is offered. OBJECTIVE: To describe the first case of implantation of a Digisonic SP® Binaural Neurelec device in Brazil (the third implant placed in the Americas, after Mexico and Colombia) and the chosen surgical approach. METHOD: Description of a surgical approach. RESULTS: The procedure was successfully completed. DISCUSSION: The squelch effect, binaural summation, location of the sound source, and the shadow effect of the head are listed among the reasons to explain the superiority of binaural rehabilitation. Cost of treatment must be considered in the development of public health policies. CONCLUSION: The cost of cochlear implants has been one of the main impediments to bilateral rehabilitation. The Digisonic SP® Binaural Neurelec device addresses this issue and exposes patients to less risk through a minimally invasive implantation procedure.


Assuntos
Adulto , Feminino , Humanos , Masculino , Implantes Cocleares , Implante Coclear/métodos , Perda Auditiva Bilateral/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Implante Coclear/instrumentação , Localização de Som , Percepção da Fala , Resultado do Tratamento
6.
Braz. j. otorhinolaryngol. (Impr.) ; 78(6): 56-62, nov.-dez. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-660412

RESUMO

O implante coclear para pacientes com disacusia grave/profunda revolucionou o modo com que estes interagem com o meio ambiente. A Neurelec desenvolveu um sistema que permite fixação com uso de dois simples parafusos de titânio, sem necessidade de broqueamento do osso do crânio do paciente. Este artigo teve o objetivo de descrever uma casuística de pacientes submetidos a implante coclear com o Digisonic® SP, para mostrar os resultados cirúrgicos e detalhes do procedimento. MÉTODO: Estudo retrospectivo que avaliou os pacientes, no período de 18 meses, submetidos a implante coclear com o Digisonic® SP. Todos os pacientes eram pós-linguais. Coleta dos dados realizada por meio da análise dos prontuários dos pacientes, além de questionário padronizado aplicado nos cirurgiões que realizaram o procedimento. RESULTADOS: Os seis casos implantados com o Digisonic® SP foram realizados por cirurgiões experientes e o tempo cirúrgico variou de 95 a 203 minutos (média de 135 minutos), que é menor do que o descrito com outras formas de fixação. Não houve nenhum tipo de complicação e o ganho auditivo foi satisfatório. CONCLUSÃO: O implante Digisonic® SP desenvolvido pela Neurelec apresentou bons resultados audiológicos em adultos, tempo de cirurgia menor e não ocorreram complicações cirúrgicas ou pós-operatórias.


Cochlear implants have revolutionized the way patients affected by severe hearing loss experience the world. Neurelec developed a fixation system with two titanium screws that requires no skull bone drilling. OBJECTIVE: To describe the outcomes and procedure-related details of a series of patients implanted with the Digisonic® SP cochlear implant. METHOD: This retrospective study analyzed patients submitted to cochlear implant placement within a period of 18 months. All patients had postlingual hearing impairment. Data was collected from patient charts and standard questionnaires answered by the surgeons in charge of carrying out the procedures. RESULTS: The six patients offered the Digisonic® SP cochlear implants were operated by experienced surgeons. The procedures took 95 to 203 minutes (mean = 135') to be completed, which is less time than what has been described for other fixation approaches. No complications were recorded and hearing improvement was satisfactory. CONCLUSION: The Digisonic® SP cochlear implant developed by Neurelec offered good audiological results for adult patients, shorter surgery time, and no surgical or postoperative complications.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Implantes Cocleares , Implante Coclear/instrumentação , Perda Auditiva/cirurgia , Parafusos Ósseos , Estudos Retrospectivos , Titânio , Resultado do Tratamento
7.
Braz J Otorhinolaryngol ; 78(6): 56-62, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23306569

RESUMO

UNLABELLED: Cochlear implants have revolutionized the way patients affected by severe hearing loss experience the world. Neurelec developed a fixation system with two titanium screws that requires no skull bone drilling. OBJECTIVE: To describe the outcomes and procedure-related details of a series of patients implanted with the Digisonic® SP cochlear implant. METHOD: This retrospective study analyzed patients submitted to cochlear implant placement within a period of 18 months. All patients had postlingual hearing impairment. Data was collected from patient charts and standard questionnaires answered by the surgeons in charge of carrying out the procedures. RESULTS: The six patients offered the Digisonic® SP cochlear implants were operated by experienced surgeons. The procedures took 95 to 203 minutes (mean = 135') to be completed, which is less time than what has been described for other fixation approaches. No complications were recorded and hearing improvement was satisfactory. CONCLUSION: The Digisonic® SP cochlear implant developed by Neurelec offered good audiological results for adult patients, shorter surgery time, and no surgical or postoperative complications.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Perda Auditiva/cirurgia , Adulto , Parafusos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Titânio , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...